THE SM32 ADVANTAGE
SM32 is suitable to power supply both single and multiple inverter systems parallel connected to a common DC link. The precharge of the leveling capacitors, which can be set via internal dip-switches, is performed by partializing the Mains voltage via an input thyristor bridge.
A diagnostic circuit allows to set the delay time for the switching off of the power thyristor during a power dip.
FEATURES
- Selection of the delay time for the thyristor switching off during a power dip (7 times, from 1.1
to 7.7 ms ± 10%) which can be selected via the dip-switches.
- Selection of the undervoltage threshold according to the power supply voltage (3 voltages:
<_370 VDC, <_ 300 VDC and <_ 80 VDC) which can be selected via the dip-switches
- Selection of the precharge time for the leveling capacitors (5 times, from 2 to 18 seconds ±
15%), which can be selected via the dip-switches
- Selection of the power supply mains frequency: 50 or 60 Hz
- Enabling, via the terminal strip, of the precharge delay.
Inputs/Outputs
- Relay outputs: 1 drive OK contact (normally open, closed after the precharge)
- 2 digital outputs: MLP signal (sum of the precharge and of the set undervoltage threshold) and
ML signal (Mains voltage monitoring).
Environmental Conditions
- Ambient temperature: from 0 to 55°C, if the temperature is higher than 40°C, reduce the current
by 1.25% every K.
- Humidity: from 5% to 85%, 1 g/m3 up to 25 g/m3 without condensing or ice formation.
- Altitude: up to 1000 meters on the sea level; if such value is exceeded, the current has to be
reduced by 1.2% every 100-meter increase.
FUNCTIONS
Protective functions: Opening of the OK relay in case of...
- overtemperature
- power supply loss on the regulation card (±15V)
- power supply loss
- completely discharged DC link
OPTIONS
Input chokes
- An input choke is compulsory for the functioning of the SM32 power supply.
|