NOTES
The Tpa2..1B converter has a single-phase Graetz rectifier bridge supplied with an RC protection filter. In order not to overcome the form factor stated by the producer, it could be necessary to supply the armature circuit with a leveling choke. The adjustment to other voltages, frequencies and tacho reaction is obtained via resistors.
FEATURES
Field power supply: Internal field rectifier
Internal reference: +10V (-10V)
Ramp circuit: 5 , 10, 25s
Reaction: Max. 300V tachogenerator, adjustment via resistors
Armature with RxI compensation, Internal connection
Enabling +15...24V : Regulation (+ramp) and Direct enabling via PLC
FUNCTIONS
Possibility for: external current limit, current regulation, regulation and power simultaneous setting, power and regulation separate power supply
LED signaling the functioning conditions
Internal switches and adjustments via dip-switches
OPTIONS
Armature with RxI compensation (External connection, by using TVO-1 card)
|