NOTES
In order not to overcome the form factor stated by the producer, it could be necessary to supply the armature circuit with a leveling choke. The adjustment to other voltages, frequencies and tacho reaction is obtained via internal switches. The converters make it possible to mount up to three “y” option cards on the rear side of the regulation card with an internal connection to the converter via a flat cable and a FA… connector.
FEATURES
Field power supply: Internal field rectifier
Internal reference: +10V
Ramp circuit: 0,5...150s
Reaction: Max. 300V tachogenerator, adjustment via resistors
Armature with RxI compensation, Internal connection
Enabling +15...24V :
- regulation (+ramp)
- ramp
- reference
- direct enabling via PLC
Connection for external indicators of armature current and speed, converter internal tuning
FUNCTIONS
Possibility for: external current limit, current regulation, regulation and power simultaneous setting, power and regulation separate power supply
Possibility for an internal mounting of the “…y” option cards (max 3)
LED signaling the functioning conditions
Internal switches and adjustments via dip-switches
OPTIONS
Speed threshold signal (with contact and +24V), by using RVy card
Armature with RxI compensation (External connection, by using TVO-1 card)
|